Temperature-Controlled Battery Short-Circuit Tester 6003C

Temperature-Controlled Battery Short-Circuit Tester 6003C

Short circuit stop mode can be selected: 1. Short circuit time; 2. Battery surface temperature.
Contact sales rep for prices

Selected items     Inventory 0

No selection yet
联系客服 Contact CS
Product desciption
Comments
FAQ

Test standard requirements:

(1) External short circuit at normal temperature: (control ambient temperature reaches 20℃± 5℃);

(2)High-temperature external short-circuit.


  • Internal box size: 500×500×600×mm (W×D×H);

  • Temperature range: RT + 10℃~85℃ (adjustable);

  • Temperature fluctuation: ±0.5℃;

  • Temperature departure: ±2℃;

  • Working voltage: The AC is 220V 50Hz~ 60Hz;

  • Impulse voltage: AC 1kv/1.2-50μ s (peak) 1min;

  • Maximum short circuit current: 1000A (Maximum current can be specified and customized);

  • DC response time: ≤5μs;

  • Internal resistance of the device: 80mΩ ±20mΩ;

  • Actuation time: Absorption time/release time> 30ms;

  • Voltage range: 0-100V;

  • Acquisition rate: 100ms;

  • Accuracy:±0.8%F.S (0~100V);

  • Current range: 0~1000 ADCA;

  • Acquisition rate: 100ms;

  • Accuracy: ±0.5%F.S;

  • Temperature range: 0℃~1,000℃;

  • Acquisition rate: 100ms;

  • Accuracy: ±2℃.

You might need to